Glossary

Green hydrogen glossary

Plain-language definitions of the terms behind green hydrogen plant design and cost, grouped A to Z and by plant category.

30 terms shown

A

  • AACE estimate classes rank capital cost estimates from Class 5 (concept screening) through Class 4 (feasibility) to Class 1 (check estimate), each with a typical accuracy range.

  • AdditionalityRegulation

    RFNBO additionality requires the power behind EU-compliant hydrogen to come from new, unsubsidised renewables, in operation no earlier than 36 months before the electrolyzer (Art. 5, Reg. 2023/1184).

  • Alkaline water electrolysis (AWE) splits water into hydrogen and oxygen in an alkaline electrolyzer filled with liquid potassium hydroxide; it is the longest-established electrolysis technology for large plants.

C

  • Capacity FactorCFRenewable input

    Electrolyzer capacity factor is the hydrogen a plant actually produces in a year divided by what it would produce running at full rated power every hour; it is one of the strongest levers on LCOH.

  • CurtailmentRenewable input

    Curtailment in green hydrogen is renewable electricity a solar or wind plant could produce but the electrolyzer cannot absorb, because power is above its rating or below its minimum load.

  • Cycles of ConcentrationCOCWater & cooling

    Cycles of concentration (COC) in a cooling tower is the ratio of dissolved solids in the circulating water to those in the make-up water; it sets how much blowdown is needed.

D

  • Delivered vs produced hydrogen is the gap between hydrogen leaving the stack and hydrogen reaching the offtaker after plant losses; a credible LCOH divides cost by delivered kilograms.

  • A deoxo unit removes residual oxygen from electrolytic hydrogen by reacting it with hydrogen over a catalyst to form water; in deoxo hydrogen purification, the dryer then removes that water.

G

  • Gas crossover is hydrogen leaking through the electrolyzer separator into the oxygen side; hydrogen in oxygen crossover sets the electrolyzer's safety trips and minimum load.

  • RFNBO geographic correlation requires contracted renewable power to come from the electrolyzer's own bidding zone or a qualifying interconnected one (Art. 7, Reg. 2023/1184).

H

  • Hydrogen compression raises hydrogen from electrolyzer outlet pressure to storage, pipeline or process pressure; hydrogen compressor types include reciprocating, diaphragm and centrifugal machines.

  • Hydrogen Purity GradesGas conditioning

    Hydrogen purity grades are minimum quality specifications set by end use; for hydrogen purity, ISO 14687 defines them, with Grade D for PEM fuel-cell road vehicles requiring at least 99.97 %.

L

  • The levelized cost of hydrogen (LCOH) is the constant price per kilogram at which a hydrogen plant recovers all its discounted costs over its life; LCOH calculation uses discounted cash flow.

  • LHV vs HHV EfficiencyLHV / HHVElectrolysis

    LHV vs HHV hydrogen efficiency is a choice of energy basis: 33.3 kWh/kg (lower heating value) or 39.4 kWh/kg (higher heating value), which changes one electrolyzer's quoted efficiency.

  • Loss of power supply probability (LPSP) is the share of demand an energy system fails to meet over a period; in hydrogen plants, it measures how much of the offtake goes unserved.

M

  • Electrolyzer minimum load is the lowest share of rated power at which the stack can run safely; below it, the unit must go to standby or shut down.

P

  • P50 / P90 Energy YieldRenewable input

    P50 and P90 solar and wind yield are annual energy estimates exceeded with 50 % and 90 % probability; lenders typically size project debt on the P90 value.

  • PEM ElectrolysisPEMElectrolysis

    PEM electrolysis splits water using a solid proton exchange membrane as electrolyte; a PEM electrolyzer responds in seconds to power changes but relies on iridium and platinum catalysts.

  • Polarization CurveElectrolysis

    A polarization curve in electrolysis plots cell voltage against current density; it shows how much extra voltage, and so extra energy, each step up in hydrogen output costs.

  • A pre-FEED study and FEED are the front-end engineering stages that take a hydrogen project from a chosen concept to a design and cost estimate firm enough for investment.

R

  • Renewable fuels of non-biological origin (RFNBO) are the EU category for fuels, such as green hydrogen, whose energy comes from renewables other than biomass; only RFNBOs count toward EU targets.

S

  • Solid Oxide ElectrolysisSOECElectrolysis

    Solid oxide electrolysis (SOEC) splits steam at high temperature on a ceramic electrolyte; an SOEC electrolyzer uses less electricity per kilogram than AWE or PEM when external heat is available.

  • Electrolyzer specific energy consumption (SEC) is the electricity, in kWh/kg, needed to produce one kilogram of hydrogen, measured either at the stack or for the whole system.

  • Stack DegradationElectrolysis

    Stack degradation is the gradual loss of electrolyzer cell performance over operating time, usually given as an electrolyzer degradation rate in %/1,000 h or µV/h of cell voltage rise.

T

  • RFNBO temporal correlation requires hydrogen to be produced in the same period as its renewable power: monthly until 2029, then hourly matching from 2030 (Art. 6, Reg. 2023/1184).

  • TSA DryingTSAGas conditioning

    TSA drying removes water vapour from hydrogen on adsorbent beds that are regenerated by heating; TSA vs PSA hydrogen drying is a trade-off between heat demand and hydrogen loss.

U

  • Ultrapure Water (RO + EDI)UPWWater & cooling

    Ultrapure water is the deionised feed an electrolyzer needs; water treatment for electrolysis typically chains reverse osmosis (RO) and electrodeionization (EDI) to remove salts that would damage the stack.

W

  • Water intensity is how much water it takes to produce 1 kg hydrogen; electrolysis needs about 9 litres per kilogram for the reaction, and several times more once cooling is included.

  • WACC is the blended return a project must pay its lenders and equity investors; in a hydrogen project, WACC is the discount rate that turns upfront CAPEX into a cost per kilogram.

  • Working inventory is the hydrogen a storage system can deliver between its maximum and minimum operating pressures; hydrogen buffer storage sizing is based on it, not on total gas held.